MS models use your existing compressed air to make foam. MSC models have a compressor built in, so no air supply is needed.
Wall, MSC on trolley
MSC & MS ULTRA 0106
The compact station. Simple to use and quick to install.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals: 2
Foam air: Air supply or compressor
Wall
MS 0112
The most powerful station in the range, with a Grundfos IE5 pump.
Pressure: 14 bar
Flow: 40 L/min
Chemicals: 3
Foam air: Air supply or compressor
Wall
MS ULTRA 0106 XA
Makes foam without compressed air, using the Turbo Foam nozzle.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals: 2
Foam air: None needed
One handle.
Every step.
No start button, no air valve, no separate compressor switch. Turn the handle to the icon you need, open the gun, and the station does the rest.
- 01Connect water, power and chemicals. Plus air for foam, or the built-in compressor.
- 02Attach a hose with a nozzle, or a foam gun.
- 03Turn the handle to rinse or one of the chemicals.
- 04Clean. Open the gun and the pump starts. Close it and it stops.
Specifications. Side by side.
The three stations above, compared on everything that separates them.
Compact, 2 chemicals
MSC & MS ULTRA 0106
Pump pressure (at 3 bar inlet): 8.5 bar
Water flow (max.): 30 L/min
Chemicals (one outlet): 2
Inlet pressure: 2 to 4 bar
Water temperature (max.): 70 °C
Foam air: Air supply or compressor
Pump start: Flow switch
Power (max.): 0.5 + 0.75 kW
Voltage: 1 × 220 to 240 V
Accessories: Choice of standard kits
Trolley option: Yes, MSC version only
Most power, 3 chemicals
MS 0112
Pump pressure (at 3 bar inlet): 14 bar
Water flow (max.): 40 L/min
Chemicals (one outlet): 3
Inlet pressure: 2 to 10 bar
Water temperature (max.): 70 °C
Foam air: Air supply or compressor
Pump start: Frequency controlled
Power (max.): 1.1 kW
Voltage: 1 × 220 to 240 V
Accessories: Full nozzle set
Trolley option: Not available
No compressed air
MS ULTRA 0106 XA
Pump pressure (at 3 bar inlet): 8.5 bar
Water flow (max.): 30 L/min
Chemicals (one outlet): 2
Inlet pressure: 2 to 4 bar
Water temperature (max.): 70 °C
Foam air: None, Turbo Foam nozzle
Pump start: Flow switch
Power (max.): 0.5 + 0.75 kW
Voltage: 1 × 220 to 240 V
Accessories: Kits 3 and 4 with Turbo Foam
Trolley option: Not available
Need it mobile?
MSC comes on a trolley.
The trolley version is only available for the MSC 0106. Because the compressor is built in, the station needs no air supply, so it works wherever there is water and power.
Built-in compressor
No air supply to connect, wherever you roll it.
Same station, same specs
8.5 bar, 30 L/min and 2 chemicals, as on the wall.
Moves between rooms and sites
One station can serve several areas.
Find the station that matches your plant.
Which one fits?
MS ULTRA 0106
Air: Air supply
Air title: Air source
Chemicals title: Chemicals
Mount title: Mounting
Air info: Uses the compressed air you already have on site.
Chemicals: 2
Chemicals info: Compact station.
Mount: Wall
Mount info: Hangs on the wall in the production area.
Why: Simple to use and quick to install, using your existing air supply for foam.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals out: 2
MS 0112
Air: Air supply
Chemicals: 3
Chemicals info: More power.
Mount: Wall
Why: The most powerful station in the range, with a Grundfos IE5 pump.
Pressure: 14 bar
Flow: 40 L/min
Chemicals out: 3
MSC ULTRA 0106
Air: Compressor
Air info: Built into the station. No air supply needed.
Chemicals: 2
Mount: Wall
Why: The compressor is built into the station, so you only need water and power.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals out: 2
MSC 0112
Air: Compressor
Chemicals: 3
Mount: Wall
Why: More power and three chemicals, with a built in compressor.
Pressure: 14 bar
Flow: 40 L/min
Chemicals out: 3
MS ULTRA 0106 XA
Air: No air
Air info: Foam from the Turbo Foam nozzle, without compressed air.
Chemicals: 2
Mount: Wall
Why: Makes foam without compressed air, using the Turbo Foam nozzle.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals out: 2
MSC ULTRA 0106 on trolley
Air: Compressor
Chemicals: 2
Mount: Trolley
Mount info: Rolls between rooms. Needs only water and power.
Why: The same station on a trolley, so one unit can serve several areas.
Pressure: 8.5 bar
Flow: 30 L/min
Chemicals out: 2
One handle.
Three steps.
No start button, no air valve, no separate compressor switch. The station does the thinking, so the operator can focus on the clean.
What is the difference between MS and MSC?
XA models make foam without compressed air. Instead, they use our Turbo Foam nozzle, which is included in standard accessory kits 3 and 4.
0106 or 0112: which should I choose?
Choose the 0106 for a compact, simple station with 2 chemicals, 8.5 bar and 30 L/min. Choose the 0112 if you need more power: 3 chemicals, 14 bar, 40 L/min and a wider inlet pressure range of 2 to 10 bar.
Can I get a station on a trolley?
Yes, the MSC 0106 can be delivered mounted on a trolley. It is the same station with the same specifications, and because the compressor is built in, it works wherever there is water and power.
Have a project in mind?