Baseline Satellite.

The standard Satellite for everyday rinse and foam. Two chemicals, one handle, at 27 or 50 bar.

The range.

Baseline Satellites for two chemicals, on the wall or on a trolley.

Wall

SU Baseline 0127

The everyday Satellite for rinse and foam.

Pressure: 27 bar

Flow: 50 L/min

Chemicals: 2

Users: 1

Wall

SU Baseline 0150

The same Satellite, built for higher pressure.

Pressure: 50 bar

Flow: 50 L/min

Chemicals: 2

Users: 1

One handle.
Every step.

No start button, no air valve, no separate compressor switch. Turn the handle to the icon you need, open the gun, and the station does the rest.

  1. 01Connect water from your Main Station or Booster, plus power and air for foam.
  2. 02Attach a hose with a nozzle, or a foam gun.
  3. 03Turn the handle to rinse or one of the chemicals.
  4. 04Clean. Open the gun and the pump starts. Close it and it stops.
Rinse
Try it. Turn the handle or tap an icon.

Specifications. Side by side.

Product specifications for both Satellites.

27 bar, two chemicals

SU Baseline 0127

Pump pressure (max.): 27 bar

Water flow (max.): 50 L/min

Chemicals (one outlet): 2

Simultaneous users: 1

Water temperature (max.): 70 °C

Functions: Rinse, foam

Rinsing nozzle: High Impact

Water supply: Main Station or Booster

Mounting: Wall

50 bar, two chemicals

SU Baseline 0150

Pump pressure (max.): 50 bar

Water flow (max.): 50 L/min

Chemicals (one outlet): 2

Simultaneous users: 1

Water temperature (max.): 70 °C

Functions: Rinse, foam

Rinsing nozzle: High Impact

Water supply: Main Station or Booster

Mounting: Wall

One handle.
Three steps.

No start button, no air valve, no separate compressor switch. The station does the thinking, so the operator can focus on the clean.

1ConnectPower, water and chemicals. Plus air on MS models.
2AttachA hose with a nozzle or a foam gun.
3Turn the handlePick water or a chemical. The pump starts when you open the gun.

Questions about
the Baseline Satellite?

Can't find your answer?

Call +45 2250 3900.

Pressurised water from a Main Station or a Booster, plus compressed air at 5 to 10 bar for foam.

The first two digits are the number of users, the last two are the maximum pressure in bar. SU 0127 is one user at 27 bar.

Choose 0150 when the plant needs higher pressure at the nozzle. Everything else is the same.

Yes. The mobile version is the same Satellite on a trolley, with a holder for the chemical and the nozzles.